Differences between GB 27789-2011 and ASTM D6878:2008

GB 27789-2011 and ASTM D6878:2008 are standards related to roofing materials, but they apply to different regions and have some differences in scope, focus, and technical requirements.

Overview of the Standards

  • GB 27789-2011: This is the Chinese national standard for thermoplastic polyolefin (TPO) roofing membranes. GB stands for "Guobiao," the abbreviation for Chinese national standards. The 2011 version specifies requirements for TPO waterproofing materials used in roofing applications in China.

  • ASTM D6878-2008: This is the American standard for TPO roofing membranes, set by ASTM International, which focuses on the physical and performance characteristics of TPO membranes used in roofing in the U.S.

Key Differences

  1. Standard Issuing Bodies

    • GB 27789-2011: Issued by the Standardization Administration of China, it is focused on the Chinese market and local climate and installation practices.

    • ASTM D6878-2008: Developed by ASTM International, it is widely used in North America and internationally as a benchmark for TPO roofing membranes.

  2. Testing and Performance Requirements

    • GB 27789-2011: This standard covers testing for tensile strength, elongation, tearing resistance, heat aging, and other properties specific to Chinese climate conditions. It may focus more on parameters that are important for local building codes and construction practices.

    • ASTM D6878-2008: This standard includes detailed testing for physical properties such as thickness, tensile strength, puncture resistance, and seam strength. ASTM D6878 also emphasizes UV resistance and heat aging, which are critical for TPO roofs in the U.S., especially in regions with high sun exposure.

  3. Climate Considerations

    • GB 27789-2011: The performance criteria take into account the specific environmental factors and weather conditions in China, such as resistance to pollution, acid rain, and seasonal temperature variations.

    • ASTM D6878-2008: This standard is designed with a focus on U.S. climates, particularly hot and sunny conditions that require TPO membranes to have excellent UV resistance and temperature performance.

  4. Thickness and Material Properties

    • GB 27789-2011: This standard may prescribe different ranges for TPO membrane thickness, focusing on certain local roofing practices and building codes.

    • ASTM D6878-2008: Specifies the minimum and maximum thickness requirements, focusing on consistency in manufacturing and durability. The U.S. standard might emphasize tighter tolerances for material performance.

  5. Chemical Resistance

    • GB 27789-2011: May place a greater emphasis on resistance to local pollutants and chemicals in the air, particularly in urban or industrial regions in China.

    • ASTM D6878-2008: Focuses on resistance to UV degradation and temperature extremes, with less emphasis on local pollution factors.

  6. Regional Adaptation

    • GB 27789-2011: Tailored to Chinese regulatory requirements, building codes, and installation practices.

    • ASTM D6878-2008: Designed for broader use in North America, with considerations for various climate zones across the U.S. and internationally.

Summary

  • GB 27789-2011 focuses on TPO roofing membranes for the Chinese market, addressing local climate conditions, installation practices, and environmental factors.

  • ASTM D6878-2008 is the standard for TPO roofing membranes in the U.S., with a strong emphasis on UV resistance, heat aging, and other performance characteristics needed for American climates and building codes.

Both standards serve similar purposes but are tailored to meet the specific needs of their respective regions.